How does one test if the fuel tank vent valve is still good ?
Part 8332556 valve, fuel tank.

Should I be able to blow air through it ?

Brian
Brian
1955 M170
1940 BSA M20
User avatar
wesk
Site Administrator
Site Administrator
Posts: 16449
Joined: Sun Apr 03, 2005 6:00 pm
Location: Wisconsin
Contact:

Post by wesk »

It should flow one way. IN. Do not forget the tank has two vents. The valve on top and the filler cap. If you are having trouble with the tank not feeding the fuel pump well it is often the cap's vent valve which someone had closed for fording and forgot to open.
Wes K
45 MB, 51 M38, 54 M37, 66 M101A1, 60 CJ5, 76 DJ5D, 47Bantam T3-C & 5? M100

Mjeeps photo album: http://www.willysmjeeps.com/v2/modules. ... _album.php
User avatar
bl5211a
Jeep Enthusiast
Jeep Enthusiast
Posts: 344
Joined: Wed Dec 27, 2006 6:00 pm
Location: NC

Post by bl5211a »

Thanks , is there a crack pressure for the in valve ? Couple psi maybe ?
Brian
1955 M170
1940 BSA M20
User avatar
bl5211a
Jeep Enthusiast
Jeep Enthusiast
Posts: 344
Joined: Wed Dec 27, 2006 6:00 pm
Location: NC

Post by bl5211a »

Hey Wes , I was able to test with psi on in side , it’s cracking open at a few psi in .